UPS & Critical Power Solutions

Modular, Industrial & Backup — Modular and industrial UPS with N+1 redundancy, external battery banks and seamless transfer for data centers, factories and healthcare - scalable from kW to MW.

Request a Quote →

Product Video

See the UPS & Critical Power Solutions range in operation. Replace the placeholder below with your YouTube or Vimeo embed.

►

Product video placeholder - add your embed code here

Industrial Modular UPS — Full Specifications

XGW HM / HMH / HML modular UPS families. Parameters apply across the modular platform; frame-specific values are noted where they differ. Source: XGW Back-up UPS Catalog 2026.

Model Families

FamilyVoltage (L-L)Power rangeTypical application
HM Series380/400/415 V15 – 600 kVAGeneral data centre & industrial on global 400 V grids
HM (large frame)380/400/415 V50–600 / 62.5–500 kVAMega data centres, up to 1.8–2.0 MVA in parallel
HMH Series480 V60 – 720 kVANorth-American 480 V installations
HML Series200/208/220 V12 – 360 kVA208 V systems, edge IT, medical, light industrial

Electrical — Input

Connection3P5W (3P+N+PE)
Rated voltageHM 380/400/415 V · HMH 480 V · HML 200/208/220 V (L-L); 220/230/240 V (L-N) for HM
Rated frequency50 / 60 Hz
Input power factor> 0.99
Current distortion (THDi)< 3% at 100% linear load
Input voltage rangeHM 304–478 V full load (228 V derate 100%→75%)
HMH 384–528 V full load (288–384 V derate)
HML 166–261 V full load (125–166 V derate)
Frequency range40 – 70 Hz

Electrical — Output

TopologyOnline double conversion, 3P/3P (selected frames 3P/1P, 1P/1P)
Rated voltageHM 380/400/415 V · HMH 480 V · HML 200/208/220 V (L-L)
Rated frequency50 / 60 Hz
Output power factor1.0 (unity)
Voltage accuracy± 1.0%
Load regulation< 5% (20% → 80% → 20% step load)
Recovery time< 20 ms (0% → 100% → 0% step load)
Output THDu< 1% linear · < 5% non-linear (IEC 62040-3)
Crest factor3 : 1
Phase accuracy120° ± 0.5°
Overload — inverter110% 1 h · 125% 10 min · 150% 1 min · >150% 200 ms
Overload — bypass110% continuous · 110–125% 5 min · 125–150% 1 min · >150% 1 s

Battery & Synchronisation

Battery voltageHM / HMH ±240 VDC · HML ±120 VDC
Charging capacity20% × Pout
Charging accuracy± 1%
Sync window±0.5 – ±5 Hz (default ±3 Hz)
Slew rate0.5 – 3 Hz/s (default 0.5 Hz/s)
Transfer / response0 ms (online double conversion, no break)

Control, Communication & Mechanical

DisplayLED + 7″ / 10″ touch LCD with IoT functions; intelligent self-diagnosis, fault recording, large history storage
Communication (std)USB, RS232, RS485, dry contact, cold start, air filter
OptionsSNMP card, AS400 card, parallel kit, SPD, LBS (load bus sync)
Protection classIP20
Power module (W×D×H)442×659×174 mm (large frames) · 440×678×85 mm 2U (30 kW) · 440×555×85 mm 2U (20 kW)
Cabinet (W×D×H)600×1000×1600 / 600×1000×2000 / 1200×1100×2000 mm (HM/HMH) · 482×700/816 mm rack (HML)

Environment & Certification

Operating temperature0 – 40 °C
Storage temperature-25 – 70 °C
Humidity0 – 95% RH, non-condensing
Noise (1 m)65 dB @ 100% load (small frames) · 72 dB @ 100% load (large frames); 62 / 69 dB @ 45% load
SafetyIEC 62040-1, IEC 60950-1
EMC / EMSIEC 62040-2, IEC 61000-4-2 (ESD), -4-3 (RS), -4-4 (EFT), -4-5 (Surge)
EfficiencyHM / HMH up to 96% · HML ≥93% (normal & battery mode)

Frequently Asked Questions

Concise, citable answers for specifiers and AI search.

Modular vs monolithic UPS?

Modular scales incrementally with load and allows hot-swap modules; monolithic suits fixed, large standalone loads.

How do I size backup runtime?

Base it on critical load in kW and target minutes; external battery cabinets extend runtime well beyond the built-in bank.