Industrial Lighting — Product Lines
Six focused categories, each engineered for a distinct application and buyer.
Explosion-Proof Lighting
- Certified for explosive gas (Zone 1/2) & dust (Zone 21/22) areas
- Sealed die-cast aluminium, tempered glass, IP66 / IK08
- Flood form factors, 50–400 W · ROBUS EX families
Emergency Lighting
- Integrated emergency module on high-bay families
- Stays lit on mains failure — escape & backup
- IP65 / IK08 rugged, same envelope
High-Bay Lighting
- 9 IWAY GC families — UFO & linear, 100–300 W
- Up to 180 lm/W, IP65 / IK10, ERP Class A
- DALI, microwave sensor, plug-and-play emergency
High-Mast Lighting
- ZT181 200–1000 W · ZT143 modular floods
- Up to 178,000 lm for 20–40 m mast rings
- Ports, yards, stadiums, bridges — IP66 / IK08
Explosion-Proof Lighting — Certified for Hazardous Areas
Dust- and gas-tight luminaires for the most demanding sites — oil & gas, petrochemical, mining, shipbuilding, ports, metallurgy and heavy industrial plants. Three ROBUS explosion-proof flood families (EX01-C, EX02-A, EX02-B) carry Ex db IIC T6 Gb / Ex tb IIIC T80°C Db certification, sealed die-cast housings and tempered-glass optics.
Explosion-Proof Families
| EX01-C · Compact Flood | ISL-EX01-C-50 / 75 / 100 / 120W · 50–120 W · AC100–277 V · 120° beam · 222×189 – 262×212 mm |
|---|---|
| EX02-A · Flood (rectangular) | ISL-EX02-A-50/75/100/150/200/240/300/400W · 50–400 W · 100–480 V multi-range · 30–120° beam · up to 462×312×325 mm |
| EX02-B · Flood (round) | ISL-EX02-B-50/75/100/150/200/240/300/400W · 50–400 W · 100–480 V multi-range · 30–120° beam · up to 469×308 mm |
Shared Specification (EX01-C / EX02-A / EX02-B)
| Ex rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db (gas IIB/IIC & dust IIIC certificates available) |
|---|---|
| Input voltage | EX01-C: AC100–277 V · EX02: AC100–277 / 120–347 / 277–480 V · 50/60 Hz |
| Power range | 50 W – 400 W (per family) |
| Lumen efficacy | 140 lm/W (±5%) |
| LED brand | LUMILEDS |
| Driver brand | SOSEN |
| CCT | 3000K / 4000K / 5000K / 5700K / 6500K |
| CRI | Ra>80 (70, 90 optional) |
| Power factor | 0.95 |
| Beam angle | EX01-C: 120° · EX02: 30° / 45° / 60° / 90° / 120° |
| IP rating | IP66 |
| IK rating | IK08 |
| Life span | 50,000 Hrs |
| Working temperature | −35 °C ~ +50 °C (EX02 up to +55 °C; −40 °C on request) |
| Warranty | 5 Years |
| Construction | Die-cast aluminium, zinc-rich powder-coated finish, tempered-glass / polycarbonate lens, integrated driver junction box |
Emergency Lighting — Backup-Battery Industrial Luminaires
Keep safe illumination when the mains fails. Our ELEGANT high-bay families — UFO HB08 and linear HB11 — are offered with an integrated Emergency battery-backup module: the same IP65 / IK08 rugged envelope, now with a self-contained emergency supply for escape routes, plant aisles and car parks.
Emergency-Capable Families
| UFO High Bay — HB08 | ISL-UFO-H100W / H150W / H200W / H240W · 100–240 W (60–240 W power-adjustable) · Ø259–373 mm |
|---|---|
| Linear High Bay — HB11 | ISL-HB11-A-100 / 150 / 200 / 240 / 300W · 100–300 W (60–300 W power-adjustable) · IK10 option |
Shared Specification (Emergency Variant)
| Input voltage | AC100–277 V · 50/60 Hz |
|---|---|
| Lumen efficacy | 150 / 170 / 190 lm/W (±5%) |
| LED brand | LUMILEDS |
| Driver brand | PHILIPS / SOSEN |
| CCT | 3000K / 4000K / 5000K / 5700K / 6500K · 3CCT adjustable |
| CRI | Ra>80 (70, 90 optional) |
| Power factor | 0.95 |
| Beam angle | 60° / 90° / 120° (HB08) · 60° / 90° / 110° (HB11) |
| IP rating | IP65 |
| IK rating | IK08 (HB11 IK10) |
| Life span | 50,000 Hrs |
| Working temperature | −35 °C ~ +50 °C |
| Warranty | 5 Years |
| Certification | UL / CCC / CB / CE / SAA / FCC / RoHS |
| Emergency function | Integrated battery-backup option — maintains illumination on mains failure (runtime & battery quoted per project) |
High-Bay LED Lighting — IWAY GC Series
Nine UFO and linear high-bay families for warehouses, plants, gyms and retail sheds — 100–300 W, up to 180 lm/W, IP65 / IK10, with plug-and-play emergency, CCT/power selection and DALI or microwave-sensor control. ERP Class A driver options.
High-Bay Families
| GC377 · UFO | 100–240 W · 160/180 lm/W · AC130–277 V · IP65 / IK10 · 60–90° / 100–120° · ERP Class A driver · 20 W emergency module, bracket, safety rope, grid guard, lamp shades optional |
|---|---|
| GC396 · UFO Slim (New) | 100/150/200 W · 130–180 lm/W · plug-in driver · power & 3-CCT dip-switch selectable · emergency, DALI 0-10V, microwave/motion sensor optional · IP65 / IK08 |
| GC389 · UFO (New) | 100/150/200 W · 166/180 lm/W · AC130–277 V · IP65 / IK08 · CCT 3000–6500 K selectable · 3-phase dimming, DALI 1-10V, microwave/motion sensor optional |
| GC383 · UFO | 100–240 W · 120–130 lm/W · AC120–277 V · pole / bracket / safety-rope mounts · CCT & power selectable · emergency backup optional |
| GC368 · UFO High-Temp | 100/150/200 W · 150–155 lm/W (up to 30,000 lm) · Philips Xitanium driver · 220–240 V / 280–400 V · operation up to +65 °C · IP65 / IK10 |
| GC362 · UFO | 100/150/200 W · 160 lm/W (16,000–32,000 lm) · AC220–240 V · chain / bracket / pole mount · aluminium lampshade · UGR<23 honeycomb diffuser · 5-year warranty |
| GC381 · UFO DOB (New) | 100/150/200 W · 100/120 lm/W · DOB driver PF>0.95 · 4/10/38 kV surge (L-N + PE) · integrated microwave motion sensor optional · IP65 / IK08 · 3-year warranty |
| GC365 · Super-Slim UFO | 100/150/200 W · 100/125 lm/W · 48 mm slim body · DOB driver · IP65 / IK08 · AC220–240 V |
| GC376 · Linear High Bay | 100–300 W · 150/160/170 lm/W (up to 30,000 lm) · IP20 (IP44) / IP65 · DALI 0/1-10V, daylight & microwave/PIR/Zigbee sensor · plug-and-play emergency & sensor interface |
Selection Guide
| Power range | 100 W – 300 W across families · power-adjustable options on selected families |
|---|---|
| Efficacy | up to 180 lm/W |
| Input voltage | AC120–277 V / AC130–277 V / AC220–240 V / 280–400 V (by family) · 50/60 Hz |
| CCT | 3000K / 4000K / 5000K / 6500K · 3-CCT & power dip-switch selectable (GC396 / GC389 / GC383) |
| CRI | Ra>80 |
| IP & IK rating | IP65 / IK08–IK10 · linear GC376: IP20 (IP44) or IP65 |
| Controls & sensors | DALI 0/1-10V · 3-phase dimming · microwave / PIR motion · Zigbee · daylight sensor |
| Emergency option | plug-and-play battery-backup module (GC377: 20 W) on UFO & linear families |
| Mounting | hook / chain / bracket / pole mount · safety rope, grid guard, lamp shades optional |
| Warranty | 3–5 years by family |
High-Mast & Stadium Flood Lighting — ZT Series
Asymmetric high-output floods engineered for 20–40 m mast rings, ports, container yards, stadiums and bridges — up to 178,000 lm per fixture, 19 kV surge protection, tool-free module replacement and anti-glare visors.
Mast Flood Families
| ZT181 · High-Output Flood | 200/400/600/800/1000 W · 36,000–178,000 lm · up to 180 lm/W · AC120–277 V · 10°/15°/30°/45°/60°/90° · IP66 / IK08 · 19 kV surge · bracket / pole / hoop mounts · gunsight aiming, anti-glare visor, safety rope, anti-collision net optional · 5-year warranty |
|---|---|
| ZT143 · Modular Flood | 320/640/960 W modular · 38,400–134,400 lm · 130–140 lm/W · AC120–277 V · 15°/25°/60°/90° · asymmetric 10°×110° / 30°×90° / 60°×90° · CRI 70/80 · DALI 0/1-10V · anti-glare visor · tool-free module replacement · 5-year warranty |
Popular Mast & Stadium Models
| ZT181-200 | 200 W · 36,000 lm · 180 lm/W · 10°–90° |
|---|---|
| ZT181-400 | 400 W · 72,000 lm · 180 lm/W · 10°–90° |
| ZT181-600 | 600 W · 108,000 lm · 180 lm/W · 10°–90° |
| ZT181-800 | 800 W · 144,000 lm · 180 lm/W · 10°–90° |
| ZT181-1000 | 1000 W · 178,000 lm · 178 lm/W · 10°–90° |
| ZT143-320 | 320 W · 38,400–44,800 lm · 130–140 lm/W · 15°/25°/60°/90° + asymmetric |
| ZT143-640 | 640 W · 79,000–89,600 lm · 139–140 lm/W · 15°/25°/60°/90° + asymmetric |
| ZT143-960 | 960 W · 114,000–134,400 lm · 139–140 lm/W · 15°/25°/60°/90° + asymmetric |
Selection Guide
| Power range | ZT181: 200–1000 W · ZT143: 320–960 W modular |
|---|---|
| Lumens | up to 178,000 lm (ZT181-1000) · up to 134,400 lm (ZT143-960) |
| Efficacy | up to 180 lm/W |
| Input voltage | AC120–277 V · 50/60 Hz |
| CCT | 4000K / 5000K / 5700K |
| CRI | Ra70 (Ra80 optional) |
| Beam angles | 10°–90° · asymmetric 10°×110° / 30°×90° / 60°×90° (ZT143) |
| IP & IK rating | IP66 / IK08 |
| Surge protection | 19 kV (ZT181) |
| Controls & sensors | DALI 0/1-10V (ZT143 optional) |
| Mounting | bracket / pole / hoop · gunsight aiming, anti-glare visor, safety rope, anti-collision net |
| Applications | 20–40 m mast rings · ports · container yards · stadiums · gymnasiums · bridges · façades |
| Warranty | 5 Years |
OEM, ODM & EPC Supply
We manufacture to spec for distributors, brand owners and engineering contractors worldwide.
Custom Engineering
Voltage, spectrum, form factor and branding tailored to your market.
Quality System
ISO 9001 controlled production with CE/FCC/RoHS compliance documents.
Global Logistics
EXW/FOB/CIF terms, consolidated shipments and after-sales support.
Frequently Asked Questions
Concise, citable answers — written so AI search engines can quote them directly.
What certification do explosion-proof lights require?
For European and most international projects, explosion-proof fixtures need ATEX (2014/34/EU) or IECEx certification matched to the hazard zone — Gas Zone 1/2 or Dust Zone 21/22. In North America, look for UL844 / NEC Class I Division 1 or 2. We supply fixtures with the correct Ex rating and a documented certificate so EPCs and inspectors can verify compliance before energising.
What is the difference between IP65 and IP69K for industrial lights?
IP65 resists low-pressure water jets and dust; IP69K (per IEC 60529) survives 100-bar, 80°C high-pressure washdown from any angle. Food, pharma and wash-down plants need IP69K; a standard IP65 fixture fails under routine pressure cleaning within 6–12 months. Specify IP69K wherever hoses or sanitation tunnels are used.
How do I choose the right high-bay wattage for my ceiling height?
Match lumens to target lux, not watts. As a rule: 6–9 m ceilings use ~100–200W (150 lm/W); 10–14 m use ~200–400W; 15 m+ use 400W+. For a 10 m warehouse targeting 200 lux, plan roughly 30–40 lm per sq ft of floor. We provide a free lux-layout so you hit the target uniformly (±5%) without over-specifying.
How is high-mast lighting maintained?
High-mast rings use a remote, ground-level driver cabinet so technicians service power without a boom lift. Modules are hot-swappable and individually fused. We recommend a 5-year service plan with spare-module kits for ports and yards running 24/7.
UFO or linear high bay — which fits my warehouse?
UFO high bays (GC377 / GC396 / GC368) concentrate light through 60–90° optics — best for rack aisles, 8–15 m ceilings and HPS/metal-halide retrofits. Linear high bays (GC376) spread wide 110° light over open floors and production lines, mount at 4–8 m and accept plug-and-play sensors. Both families offer emergency battery-backup and DALI/sensor control — we size fixture counts in a free lux-layout.
Product Video & Datasheet
Watch the Industrial Lighting range in action and download the full specification sheet (PDF).